Affected software versions do not allow the dual-speed J8177C to be configured for 100 Mbps operation, responding with a message such as "Value auto-100 is not applicable to <port number>". The 100 Mbps settings should be supported for the J8177C Gigabit-copper transceiver on the 5400zl, 6200yl, and 8200zl switches running software versions K.12.21 and later.
This issue affects the J8177C HP X121 1G SFP RJ45 T Transceiver when it is installed in a switch running one of the following affected software versions:K.15.09.0001 through K.15.09.0015K.15.10.0003 through K.15.10.0012K.15.11.0003 through K.15.11.0007K.15.12.0006 and K.15.12.0007
The Lab has a fix, documented in CR_0000132781. The fix has been added to K.15.09.0016 (released, and available from support). Software versions with the fix will be posted on the web as soon as possible.WORKAROUNDBack-rev to a version of software that works. These software versions are not affected, and are available on the web today:K.15.07.0015K.15.08.0014HP regrets any inconvenience this may cause.