Once the drives on an HPE Smart Array Gen11 or Gen10 Plus Controller have failed, the logical drive and controller alert in OneView remains in critical (red) status, until the logical drive is re-enabled via one of the Smart Array configuration tools.Failed Physical Drive ImageHowever, OneView will not clear the Critical Drive alert even after the failed drive is inserted and the Logical volume is re-enabled via one of the Smart Array configuration tools.Reenable Volume Image
The following HPE Smart Array controllers are impacted by this issue:HPE Smart Array Gen11 controllers:HPE SR416ie-m Gen11 x16 Lanes 4GB Cache SPDM Mezzanine Storage Controller (P39959-B21)HPE SR932i-p Gen11 x32 Lanes 8GB Wide Cache PCI SPDM Plug-in Storage Controller (P47184-B21)HPE Smart Array Gen10 Plus controllers:HPE SR416i-a x16 Lanes 4GB Cache NVMe/SAS 24G Controller for HPE Gen10 Plus (P12688-B21)HPE SR932i-p x32 Lanes 8GB Wide Cache NVMe/SAS 24G Controller for HPE Gen10 Plus (P04220-B21)Operating systems affected:Microsoft Windows Server 2019Microsoft Windows Server 2022VMware ESXi 7U3VMware ESXi 8U2 and 8U3Red Hat Enterprise Linux 8Red Hat Enterprise Linux 9Suse Enterprise Linux 15
This issue is resolved inHPE Synergy Service Pack - SY-2024.11.01(or later).As a workaround, follow the steps below to manually clear the alert in OneView.Log intoHPE OneViewwith Administrator Privileges.Go to the OneView Main Menu and selectOption Activity.Click on theFiltericon at the top-right-side of the screen. Filter for “Active” Alerts. Under the filter screen, click onState “Active”.Clear The Volume Failed Alert as shown in the snapshot below.Example of Clear AlertExample of All Alerts ClearRevision HistoryDocument VersionRelease DateDetails2January 23, 2025The Resolution was updated with the version of HPE Synergy Service Pack (SSP) that resolves this issue.1May 17, 2024Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.