After upgrading drive firmware from version HPK2 to version HPK3, the following issues may occur on certain HPE NVMe SSDs (listed in Scope), for example:The LED on the front of the disk will illuminate solid amberThe disk will be marked as "Critical/failed" in the HPE Integrated Lights-Out (iLO) User Interface shown under the Storage tabThe disk will be in "Read Only" mode, so it cannot be written to any longerThe Integrated Management Log (IML) will show a failed disk, for instance:"Critical,NVMe,NVMe Storage - Drive at Embedded:Port=9B:Box=1:Bay=2 status changed to Failed,01/07/2026 23:55:15,274,Hardware, Critical,NVMe,NVMe Storage - Drive at Embedded:Port=9B:Box=1:Bay=1 status changed to Failed,01/07/2026 23:55:15,274,Hardware"In addition, if tools such as SmartCTL are used, after the updgrade the output will show an example similar to the following health status:=== START OF SMART DATA SECTION ===SMART overall-health self-assessment test result: FAILED!NVM subsystem reliability has been degradedmedia has been placed in read only mode
The following HPE SSDs and storage option kits are susceptible to this issue:HPE Part NumberHPE Spare Part NumberHPE Model NumberHPE DescriptionP70392-B21P70490-001VV003840KYFFHHPE 3.84TB NVMe RI E3S EC1 PS1010 SSDP70395-B21P70491-001VV007680KYFFLHPE 7.68TB NVMe RI E3S EC1 PS1010 SSDP70397-B21P70492-001VV015360KYFEVHPE 15.36TB NVMe RI E3S EC1 PS1010 SSDP70399-B21P70493-001MV003200KYFFKHPE 3.2TB NVMe MU E3S EC1 PS1030 SSDP70401-B21P70494-001MV006400KYFFAHPE 6.4TB NVMe MU E3S EC1 PS1030 SSDP70403-B21P70495-001MV012800KYFFBHPE 12.8TB NVMe MU E3S EC1 PS1030 SSD
NOTE: HPE recommends tonotupdate the disk drives to firmware HPK3 and wait for a future firmware that can correct these issues.If the firmware has been updated and issues have occurred, perform one of the following options:To recover the disk, use the Linux command "nvme format /dev/xxx" where xxx is the device name, i.e. /dev/nvme0n1. This will make the disk usable again.ORReplace the disk drive if the first option is not possible.Contact HPE Customer Support if further assistance is needed through your localcountry HPE Customer Supportor log a case via theHPE Support Center.
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.