If the Lightweight Directory Access Protocol (LDAP) login is used for Integrated Lights-Out (iLO) and the user is a member of more than 300 groups (including nested groups) the LDAP login may fail. This may occur even when iLO is set up correctly and the proper username and password are being entered for the LDAP login. In some instances, the login will succeed a few times and then fail at a later login attempt.This issue will occur on all ProLiant servers with Integrated Lights-Out 3 (iLO 3), iLO 4, iLO 5, or iLO 6 firmware v1.59 when the user's directory membership exceeds the iLO's threshold amount of 300 groups. The Integrated Lights-Out has a limit set to 300 directory groups that it will support. When the group total for a user's directory exceeds this threshold, then the following error message is displayed:The test pages will also show a similar message, as shown in Figure 2 - Test Directory Settings Page:Note: With iLO 3 Firmware Version 1.80 (or later) and iLO 4 Firmware Version 2.00 (or later), the following message will be displayed on the logon page when this issue occurs:Failed login attempt, Internal Error. Login Delay required.With iLO 5 Firmware Version 2.72 (or later), the following will be displayed:
Any HP ProLiant server configured with iLO 3, iLO 4, iLO 5, iLO 6 firmware v1.59.
To resolve this issue, perform the following:For iLO 6 firmware v1.59, update to iLO 6 firmware v1.60.For iLO 3, iLO 4, or iLO 5, reduce the maximum directory group size to less than 300 including nested groups.In the future, iLO 3, iLO 4, or iLO 5 whitepapers and user guides will include information on the limit of 300 total count for the group size.To download iLO 6 v1.60, perform the following steps:Click the following link:http://www.hpe.com/support/ilo6The page should refresh to display the "DRIVERS AND SOFTWARE" tab and the components that support the selected product. From the "DRIVERS AND SOFTWARE" expandable filter menus on the left side of the page:For further filtering if needed - Select the specific Operating System from the Operating Environment.Locate and select theHPE Integrated Lights-Out 6 v1.60 firmware.click the Revision History tab to locate the latest version.For more important information, review the Release Notes tab.Click theDownloadbutton.Document VersionRelease DateDetails5August 23, 2024Added fix for iLO 6, iLO 6 firmware v1.60.4August 19, 2024Added iLO 6 firmware v1.59 as affected.3February 12, 2024Added iLO 6 as affected.2May 12, 2023Added iLO 5 as affected.1September 3, 2014Original Document Release.Supersedes c04433986 (Revision 0).
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.