After attempting a restore from an appliance backup, HPE Virtual Connect SE 100Gb F32 Module may go into a Critical state of "AddedWithErrors" with the message, "The interconnect could not be imported." It will appear in HPE OneView with the message, "Unable to claim the interconnect. (NWMN_011A)":If an HPE OneView factory reset occurs while restoring from backup, it can fail with module import failure message above.This issue will only occur with the HPE Virtual Connect SE 100Gb F32 Module for Synergy from either of the following actions:The master role is changed while the interconnect claim activity is in progress.ORThe HPE OneView appliance restore is attempted on an appliance with a backup made before the interconnect failover.However, this issue will not impact the traffic.
HPE OneView 10.20 with HPE Virtual Connect SE 100Gb F32 Module for Synergy.
After verifying the issue is the same as described above, re-apply the interconnect configuration for the module in HPE OneView. Select one the respective Logical Interconnect or Interconnect tabs in HPE OneView, and then select the "Action" menu and Reapply configuration.For information on how to reapply interconnect configuration, refer toHPE OneView 10.0 User Guide for Synergy.This issue is corrected by upgrading toHPE OneView 11.01or later.Document VersionRelease DateDetails2March 31, 2026Updated the Resolution with the permanent fix.1August 29, 2025Original Document Release.
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.