Loading...
Loading...
VersionRelease DateDetails3November 5, 2021"or Later" was changed to "Through v3.53" for Gen10 Controllers in the Title and Description sections, and the Resolution section was updated to reflect the version of firmware that resolves this issue.2February 3, 2021Minor revisions to the Title, Description, and Resolution sections.1January 14, 2021Original Document Release.HPE Smart Array SR Gen10 Controllers on v2.65 through v3.53 firmware cabled in a single domain configuration may report "Redundant Cable Problem Detected" if the D6020 has any drives configured in a logical drive.Smart Array POST or Server IML message1738 - Slot (x) Drive Array Storage Enclosure Redundant Cabling Problem Detected.This warning message can be ignored as SATA drives are single-ported devices.
HPE D6020 Disk Enclosures are affected by this issue.
This issue is resolved in HPE Smart Array SR Gen10 Controllers on v4.11 firmware.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.