When creating Creating Access Control Lists (ACLs), the industry norm is to have multiple rules per ACL. However, with the HPE Synergy 40Gb F8 Switch Module, only one rule (match criteria) per ACL is allowed. This is by design.Note that Multiple ACLs can be applied to a single interface. In addition, ACLs cannot be applied to the management interface.
Any HPE Synergy 40Gb F8 Switch Module regardless of the firmware version installed.
This ACL behavior is by design for the HPE Synergy 40Gb F8 Switch Module.When more than one rule is needed, assign multiple ACLs to a single interface with one rule each.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for HPE systems and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips Document.