The HPE Synergy 4610C 10/25G Ethernet adapter has been observed to have intermittent link issues with the Mellanox SH2200 Switch for HPE Synergy platforms with VMware ESXi as a Host Operating System (OS) and AutoNeg (AN) turned on.Both the HPE Synergy 4610C 10/25G Ethernet adapter and Mellanox SH2200 switch are AN capable devices. If the HPE Synergy 4610C 10/25G Ethernet adapter is configured to AN and the Mellanox SH2200 switch is configured to 25GbE, an anomaly is observed where an intermittent link flap causes the switch to default back to AN, which in turn causes link not to be established. If both the switch and network adapter are set to 25 GbE forced speed, the issue is not observed.Once a link is disabled and brought back up online with AN enabled on both devices, it could take up to 500 seconds for the link to be established. In lab test results with AutoNeg ON and a 200 second delay time between link flaps, failure is intermittently observed. When delay time between link flap is set to 500 seconds wait time, the test passes successfully. In 25 GbE forced speed mode with AutoNeg disabled on both devices, link is established in less than 30 seconds and link flap test iterations pass successfully.
Any HPE Synergy 4610C 10/25G Ethernet adapter.This issue may occur with all VMware ESXi releases and all versions of firmware for this card.
This issue is not seen if both the switch and network adapter are set to 25 GbE forced speed.Executing the "no-autoneg" command in the Mellanox SH2200 Switch for HPE Synergy (interface ethernet 1/15 speed 25G no-autoneg) will force speed to 25G. If the link goes up or down, speed will still remain at 25G.Note: if executing the command without the "no-autoneg" option but with the force command instead (interface ethernet 1/15 speed 25G force), link will revert back to autoneg if were to be link disabled and re-enabled. See the following table for more details:Adapter Link Speed(HPE 4610C)Switch Link Speed(Mellanox SH2200)Test Time between Link Flaps in Lab(Test is bringing link up and down via script)CommentsForced to 25GbForced to 25GbEvery 200 secondsNo link issuesAuto Negotiate onAuto-Negotiate onEvery 500 SecondsNo link issuesAuto Negotiate onAuto-Negotiate onEvery 200 secondsIntermittent link failure is observedAuto Negotiate onForced to 25GbEvery 200 secondsLink flap can cause switch to go back to AN mode and may result in link FailureAuto Negotiate onForced to 25 Gb with No-AutonegNot ApplicableIf the link goes up or down, it will still remain at 25G.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for HPE systems and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips Document.
Operating Systems Affected:VMware ESXi Server 5.x
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.