An issue has been identified where the "ScratchConfig.CurrentScratchLocation" value may default to "/scratch" if a VMware ESXi 6.5 server is configured with an iSCSI connection and if the following version of the Emulex driver and IMA-plugin is installed:elx-esx-libelxima.so 11.2.1238.0-03elxiscsi 11.2.1238.0After rebooting the server, normally the value assigned to the "ScratchConfig.CurrentScratchLocation" would equal the value currently set for "ScratchConfig.ConfiguredScratchLocation".In the example below, the Current Scratch Location does not equal the Configured Scratch Location. Instead, the value is set to "/scratch".When this occurs, the following alert message will be displayed in the /var/run/log/vmkernel.log file:"ALERT: Logs are stored on a non-persistent storage. Consult product documentation to configure a syslog server or a scratch partition."
Any HPE ProLiant server running VMware ESXi 6.5 with the following version of the Emulex IMA-plugin and driver:elx-esc-libelxima.so 11.2.1238.0-03elxiscsi 11.2.1238.0
Download and update to HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5 version 2018.02.12, that contains the Emulex library file and the Emulex iSCSI driver, at the following URL:https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4e50a0cb8be64189bf600ede8aThe files in this single component pack are:elx-esx-libelxima.so 11.4.1210.0-03elxiscsi 11.4.1210.0RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips Document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.