NDMP Backups are failing with the following error: ErrorsStatus: Failed ABNDMP0003: Unable to backup the NDMP asset because an error occurred on the Accelerator node: code 176: fatal signal (errorcode 10026). The backup task cannot be completed because an error occurred in the Accelerator node during the operation. To troubleshoot this issue: 1) Review the backup log files in the Accelerator node at /usr/local/ppdm/var/ under corresponding NAS Subsystem directory. 2) Check the error reason and code mentioned above. 3) Verify the Data Domain (DD) version, and if it is below 8.2, consider increasing the timeout setting OST_ABANDON_TIMEOUT on the Data Domain. From the NDMP Accelerator node logs, the following can be seen: 2026-05-26 14:46:27 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] avndmp Info <5174>: - [/usr/local/ppdm/bin/avndmp] Reading /usr/local/ppdm/var/netapp_ndmp/ndmp.cfg 2026-05-26 14:46:27 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] avndmp Info <16178>: [/usr/local/ppdm/bin/avndmp] Command Line: /usr/local/ppdm/bin/avndmp --fileraddr=NETAPP_CLUSTER_IP --filertype=md5 --filerpswd=**************** --filerbrand=netapp --acceladdr=ACCELERATOR_NODE --fileruser=NDMP_USER --sysdir=/usr/local/ppdm/etc/netapp_ndmp --bindir=/usr/local/ppdm/bin --vardir=/usr/local/ppdm/var/netapp_ndmp --ctlcallport=41341 --ctlinterface=7003-NDMPBTASK_ID:0f2ada5e-54b1-49c4-81db-a472c2b6914f --logtag=TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f --logfile=/usr/local/ppdm/var/netapp_ndmp/NDMPBTASK_ID:0f2ada5e-54b1-49c4-81db-a472c2b6914f-7003-Netapp_Filer.log --ctlusessl=true 2026-05-26 14:46:27 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] avndmp Info <6673>: [ctl_listen] CTL listening on port 37967 2026-05-26 14:46:28 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] avndmp FATAL <5889>: [ctl_callhome] Fatal signal 11 in pid 8407 2026/05/26-13:46:28.00905 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] FATAL ERROR: <0001> uapp::handlefatal: Fatal signal 11 2026/05/26-13:46:28.00928 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] | 00000000005b7e3f 2026/05/26-13:46:28.00930 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] | 00000000005b8ce3[...........]2026/05/26-13:46:28.00955 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] | 0000000000606513 2026/05/26-13:46:28.00956 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] | 00007f6f8cca6f6c 2026/05/26-13:46:28.00957 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] | 00007f6f8cd2e338 2026/05/26-13:46:28.00966 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] [ctl_callhome] ERROR: <0001> uapp::handlefatal: aborting program pid=8407, sig=11 2026-05-26 14:46:28 [TRACE_ID:ad6eafff27102c4e;JOB_ID:92c5a8b36c160c3c;TASK_ID:81dba472c2b6914f] avndmp FATAL <5890>: [ctl_callhome] handlefatal: Aborting program with code 176, pid=8407, sig=11
This error happened because of the host OS from which the Accelerator node was installed to. The avndmp process (version 20.1.0.1_10_1) is unresponsive with a Fatal Signal 11 (SIGSEGV — Segmentation Fault) immediately after successfully connecting to the NetApp filer. The crash occurred in the ctl_callhome function, which is the call-home telemetry module that reports status back to the PowerProtect Data Manager server.
Ensure to follow the pre-requirement and install the Accelerator node on a supported Linux Version. The accelerator node supports only SLES 15 SP6. Dell PowerProtect Data Manager 20.1 Network-Attached Storage User Guide page 38.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.