Bare mental install of the Block Volume Protection Engine 19.22.0-16 on Red Hat Enterprise Linux (RHEL) 9.6 fails to apply IP forwarding settings. The installSPP.sh script aborts when configuring IP forwarding for a VLAN interface. sysctl: cannot stat /proc/sys/net/ipv6/conf/bond0/900/temp_prefered_lft: No such file or directory sysctl: cannot stat /proc/sys/net/ipv6/conf/bond0/900/temp_valid_lft: No such file or directory sysctl: cannot stat /proc/sys/net/ipv4/conf/bond0/900/forwarding: No such file or directory sysctl: cannot stat /proc/sys/net/ipv6/conf/bond0/900/forwarding: No such file or directory Failed to apply IP forwarding settings. Performing clean up... The expected path for VLAN interface settings is /proc/sys/net/ipv6/conf/bond0.900/. [root@node01 emc-vProxy-SPP]# ls -lrt /proc/sys/net/ipv6/conf dr-xr-xr-x 1 root root 0 2024-01-21 16:02 lo dr-xr-xr-x 1 root root 0 2024-01-21 16:02 default dr-xr-xr-x 1 root root 0 2024-01-21 16:02 bond1 dr-xr-xr-x 1 root root 0 2024-01-21 16:02 bond1.910 dr-xr-xr-x 1 root root 0 2024-01-21 16:02 bond0 dr-xr-xr-x 1 root root 0 2024-01-21 16:02 bond0.900 dr-xr-xr-x 1 root root 0 2024-01-21 16:15 docker0 dr-xr-xr-x 1 root root 0 2024-01-21 16:18 all sysctl.conf entries for the VLAN interface net.ipv6.conf.bond0.900.temp_prefered_lft=86400 net.ipv6.conf.bond0.900.temp_valid_lft=86400 net.ipv4.conf.bond0.900.forwarding=1 net.ipv6.conf.bond0.900.forwarding=1
Incorrect sysctl path resolution for VLAN interfaces The installSPP.sh script fails because sysctl misinterprets interface names that contain a dot ( . ). When a VLAN interface such as bond0.900 is referenced in sysctl.conf using dot‑notation (e.g., net.ipv4.conf.bond0.900.forwarding=1 ), sysctl treats the dot as a directory separator. It constructs an invalid path like /proc/sys/net/ipv4/conf/bond0/900/forwarding instead of the correct /proc/sys/net/ipv4/conf/bond0.900/forwarding . The resulting “No such file or directory” errors prevent IP forwarding settings from being applied.
The issue is fixed in an upcoming Dell Technologies release. Before that release, the workaround is to change the VLAN name from e.g., bond0.100 to bond0-100. Note: This workaround requires the network configuration change in the customer's environment.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.