When importing the Server Configuration profile from iDRAC9, the job completes with errors. $ racadm lclog viewconfigresult -j JID_485333318994 Operation Name = CHANGE DisplayValue = "" Name = Users.16#SHA1v3Key OldValue = ****** NewValue = ****** MessageID = SYS171 Status = Failure ErrCode = 10320 Operation Name = CHANGE DisplayValue = "" Name = Users.16#MD5v3Key OldValue = ****** NewValue = ****** MessageID = SYS171 Status = Failure ErrCode = 10320 OpenManage Enterprise or OpenManage Enterprise Modular to Deploy a Template shows the Deployment job as failed. SYS055 error with failed attributes:1) Users.2#SHA1v3Key - null | iDRAC.Embedded.1 | ****** --> ******|SYS171|Not all hash password values have been supplied.|10320 2) Users.2#MD5v3Key - null | iDRAC.Embedded.1 | ****** --> ******|SYS171|Not all hash password values have been supplied.|10320
iDRAC firmware version 7.20.30.00 introduced new (SHA384v3Key/SHA512v3Key) attributes for local iDRAC user accounts. For existing iDRAC user accounts these new attributes value is null. The iDRAC configuration profile import containing SNMPv3 Enabled users require that all SNMPv3 Key attributes have values supplied.
To remediate this issue, update or reenter the iDRAC local user accounts password in order to generate the new SNMPv3 (SHA384v3Key/SHA512v3Key) values. Then re-create the reference Template or Server Config Profile. Workaround: Remove or comment the user's SNMPv3 key attributes from the Template or SCP.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.