SRM Array disconnected and showing ping errors between SRM and PowerFlex Gateway, as show the error: SRA command 'discoverDevices' failed
PowerFlex 4.5 + changed the external gateway VM to an internal container within PowerFlex Manager. Due to this, SRM lost the connectivity, as gateway IP changes to the internal container network.
When upgrading PowerFlex from 3.6 to 4.5 + it is needed to follow the following actions: 1 - Upgrade SRA to at least version 1.0.1: https://dl.dell.com/content/manual67010541-dell-powerflex-storage-replication-adapter-sra-plugin-for-vmware-live-site-recovery.pdf?language=en-us 2 - Change the array configuration at SRM to point to PowerFlex Manager FQDN/IP. After those actions, SRM should start to work back again.