Data Domain is not added to PowerProtect Data Manager 19.14 with the following error. Figure 1: Unable to add Data Domain - Handshake failed Data Domain SMS logs (sms.info) show the following error message: WARNING: smu_services_verify_dhparam_file:454 DH PARAMETER file "/root/certs/dhparam.pem" doesn't exist. ERROR: _sms_init_ssl_server_context:496:Error loading DH parameter file, DH parameter file doesn't exist
PowerProtect Data Manager is only able to complete SSL handshake when the file /root/certs/dhparam.pem is present in the Data Domain.
Contact Dell PowerProtect Data Manager Support to regenerate the file /root/certs/dhparam.pem in Data Domain.