Avamar GLR for Exchange (ItemPoint) browse does not show edb/log path in UI. On the target client (GLR Proxy) in the avexglr_plugin.log (located in Avamar VAR: C:\Program Files\avs\var ) we see the below errors: 2022-08-17 23:38:12 avexchglr Info <13046>: Manager finished 2022-08-17 23:38:12 avexchglr Info <19008>: Obtaining available VSS providers 2022-08-17 23:38:12 avexchglr Info <8871>: Gathering writer metadata... 2022-08-17 23:38:16 avexchglr Error <8801>: ERROR: Win32 call L"GetVolumePathNameW" failed. 2022-08-17 23:38:16 avexchglr Error <13350>: Exchange GLR mount and restore operations unable to complete. 2022-08-17 23:40:02 avexchglr Info <9528>: Cancel request received - no assistant or aborted assistant 2022-08-17 23:41:06 avexchglr Error <13527>: Could not set state machine to 'plugin timed out', because of STATE_EVENT_IGNORED - Ignoring requested state transition for the 'plugin_timedout' event with transition cause of 'CAUSE_PLUGIN_TIMEDOUT' while in the 'STATE_NOT_MOUNTED' state
The existing drive is mounted from Dell Elastic Cloud Storage (ECS) using GeoDrive. This causes mount issues for EldoS driver, which Avamar GLR uses.
On the target client (GLR Proxy): Unmount the drive using GeoDrive. Ensure that there is no mount present on the Proxy and retry GLR.