Unable to Edit or Break FTD-HA via FMC GUI
During the FTD-HA creation process, the operation should initially fail with the error: "High availability configuration failed on . Troubleshoot." This failure occurs due to a network connectivity issue between the FMC and FTD. Additionally, even after a successful deployment to the FTD-HA, an entry for /var/cisco/peers/ can still be observed, indicating improper cleanup. Ideally once FTD HA is created successfully the spinner icons in FMC UI should be removed. But for some reason if the entries for PRIMARY_UUID/SECONDARY_UUID/NGFWHA_UUID still remains in /var/cisco/peers/, user will not be able to break the FTD HA.
Ensure that the above condition is met and verify that the UUID in /var/cisco/peers corresponds to the NGFWHA by using the check_uuid.pl script. Once confirmed, delete the UUID file using the following command: rm /var/cisco/peers/ If you see Primary & Secondary Device UUIDs. You may want to delete the same to remove the spinner icons in FMC UI. rm /var/cisco/peers/ rm /var/cisco/peers/ Please contact BU once to confirm if any doubts.
NA