Live logs/Reports/Health Summary Dashboard are not showing on GUI. The next alarm is generated: java.sql.SQLException: java.sql.SQLException: ORA-01658: unable to create INITIAL extent for segment in tablespace MNTNS show logging application collector.log | include "ORA-01658" displays the next error ERROR [IMS System AcsSyslog store][[]] cisco.mnt.collection.syslog.AcsSyslogCollectionFailure -::::::- SQLException sent to the Collection Failure Alarm by Collector: java.sql.SQLException: java.sql.SQLException: ORA-01658: unable to create INITIAL extent for segment in tablespace MNTNS Affected tables: Posture, SXP, Active Directory, Configuration Changes, System Diagnostics,
Issue starts after installing an affected patch The incoming data volume is high causing the tablespace exhaustion
Reset MnT Database. This will temporarily release the tablespace but the issue will resurface. On the MnT nodes follow the next steps. One node first and then the other if needed - Open the ISE CLI - use the command "application configure ise" - select option 4 The node will reboot
We are likely to encounter the same issue again within 10 to 15 days after resetting the MnT database.