The setting to "ignore" or "alert" may not be set on the HPE Integrated Lights-Out 7 (iLO 7) for the "Default SSL Certificate In Use." As a result, the "Default SSL Certificate In Use" iLO setting may not be applied correctly on a OneView server profile, and an alert message may appear:"iLO Settings do not match the expected values.Resolution Review the iLO settings details for the server profile to view the inconsistent setting(s). Reapply the server profile to configure the iLO settings to match the expected values."This issue occurs due to a name change and is shown differently in the iLO security dashboard depending upon the firmware version:iLO 7 1.16 or earlier shows this setting as "DefaultSSLCertificate In Use"iLO 7 1.17 or later shows this setting as "DefaultTLSCertificate In Use"
HPE OneView 11.30 or earlier that manages a server with HPE Integrated Lights-Out 7 (iLO 7) firmware version 1.17 or later.
This issue will be fixed in a future release of HPE OneView. This advisory will be updated when more information is available.As a workaround, manually set the "Default SSL/TLS Certificate In Use" in HPE Integrated Lights-Out 7 (iLO 7).