An HPE NS204i-x Boot Device may not start, and the controller will lock up, due to a rear disk failure. After a system restart, the server stops at the BIOS Power-On Self-Test (POST) screen for over 10 minutes, and the boot device, volume, and Non-Volatile Memory Express (NVMe) Solid State Drives (SSDs) will not appear in the HPE Integrated Lights-Out (iLO) GUI or the BIOS/Platform Configuration (RBSU).
This advisory applies to the following products:HPE NS204i-p x2 Lanes NVMe PCIe3 x8 OS Boot Device (P12965-B21)HPE NS204i-u v2 480GB NVMe Hot Plug Boot Optimized Storage Device (P78279-B21)HPE NS204i-u v2 960GB NVMe Hot Plug Boot Optimized Storage Device (P81160-B21)HPE ProLiant DL36X Gen10 Plus x16/x8 PCIe M.2 NS204i-r Riser Kit (P26463-B21)HPE NS204i-t Gen10 Plus x2 Lanes NVMe PCIe 3 x8 Boot Controller (P20292-B21)HPE NS204i-d Gen10 Plus NVMe PCIe3 x4 M.2 OS Boot Device (P21410-B21)HPE NS204i-u Gen11 NVMe Hot Plug Boot Optimized Storage Device (P48183-B21)HPE Synergy NS204i-d Gen11 NVMe Boot Storage Device (P39568-B21)
If this issue occurs, follow these steps:Power off the server.Remove both drives from the server.Upgrade the HPE NS204i-x Boot Device firmware to version 1.2.14.1025 (or later).Reboot the server to check the NS204i-x Boot Device firmware version from the iLO GUI.Power off the server.Install both drives in the same bay, then restart the server. The iLO GUI should display one working drive and show the other as "Failed", or it displays a failed disk LED on the HPE NS204i-p and NS204i-u.Power off the server.Replace the failed drive. Power on the server and have the controller rebuild the volume.If the issue persists, contact HPE Support.This issue is fixed in HPE NS204 Boot Device firmware version 1.2.14.1025 and later:Firmware Package - HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-rNOTE: Firmware version 1.2.14.1026 is available, and HPE recommends updating to this version to address the issue in Customer Advisory a00156392 -Advisory: (Revision) HPE NS204i NVMe Boot Storage Boot Devices - False Drive Messages May Appear for HPE Gen11 or Gen12 Server Systems with NVMe SSDs Attached to HPE NS204i Devices.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.