On HPE ProLiant Compute Gen12 servers running HPE Integrated Lights-Out 7 (iLO 7) firmware version 1.25.xx, the iLO Configuration Utility accessed through UEFI System utilities (RBSU) F9 > System Utilities > iLO Configuration Utility > Network Options may incorrectly reject valid static IPv4 network settings.When entering or modifying a valid IPv4 address, subnet mask, or default gateway, the utility may display validation errors and prevent the configuration from being saved.For example, the utility may incorrectly report one or more of the following validation errors:"Valid octet range: (0-255).""Subnet mask IP address is invalid.""Poorly formed mask.""Invalid Configuration. An IP address is not allowed."An example of this behavior is shown below.This issue is limited to the iLO Configuration Utility (UEFI/RBSU interface). Configuration through the iLO web interface is not affected.
HPE ProLiant Compute Gen12 servers running HPE Integrated Lights-Out 7 (iLO 7) firmware version 1.25.xx.
This issue will be resolved in a future version of HPE Integrated Lights-Out 7 (iLO 7) firmware.As a workaround, perform either of the following:Downgrade to HPE iLO 7 firmware version 1.24.00, where the issue is not present.ORUse the iLO Service Port to configure iLO network settings.