HPE OneView versions 11.40 and 11.50 running on an HPE Synergy Composer2 Plus appliance may report a critical GEC_182 error following a frame cold power- cycle. When this issue occurs, the GEC_182 error is displayed in HPE OneView and the HPE OneView appliance cluster may fail to form, preventing normal cluster operation.This behavior is caused by a timing issue during HPE Integrated Lights-Out (iLO) initialization following a frame cold power-cycle. The issue has not been observed when only the Composer2 Plus appliance is independently reseated or power-cycled.There is no data loss or configuration loss associated with this issue.
HPE OneView versions 11.40 and 11.50 running on HPE Synergy Composer2 Plus appliances with HPE Integrated Lights-Out (iLO) 7 version 1.23 or 1.25 in HPE Synergy frames that undergo a frame cold power-cycle.
To recover from this condition, reseat or power-cycle the affected HPE Synergy Composer2 Plus appliance. Performing this action allows the HPE OneView appliance cluster to reform and resume normal operation.No data loss or configuration loss occurs as a result of this issue.HPE is investigating a permanent fix for this issue. This advisory will be updated when additional information becomes available.
Operating Systems Affected:Not Applicable