Importing or linking SQL/MX tables using Microsoft Access with ODBC/MX driver fails with -7732 error. The fix in T7968 described in the original HotStuff was temporary and the customers on L38 and L39 are recommended to use the fix provided in T0611.Microsoft Access gets the external database tables using either import tables or linked tables option. When importing SQL tables of SQL/MX R3.8.x or R3.9 version, Microsoft Access tries to get columns information, which fails with -7732 error. This problem can happen in interoperability scenario where the table resides in lower SQL/MX versions like L38 or L39 and accessed from L40. Customers are recommended to use the permanent fix provided in T0611 instead of the temporary fix provided in T7968 as described in the original HotStuff.Likelihood: Certain under the stated conditions
Affected Software Product Revisions (SPRs):T0611L38 - T0611L38^AURT0611L39 - T0611L39^AUORelease Version Updates (RVUs) containing one of the affected SPRs:L21.11.00 - L25.02.02
RVU containing final fix:L25.09PREVENTIVE ACTION:Workaround:NoneFix:Install the appropriate SPRs for T0611 as shown below, based on your release version.L38:T0611L38^AUT (SQLMX Modules)This SPR already is present in these RVUs: NoneThis SPR is usable with the following RVUs:L21.11.00 - L25.02.02L39:T0611L39^AUS (SQLMX Modules)This SPR already is present in these RVUs: NoneThis SPR is usable with the following RVUs:L24.08.00 - L25.02.02Installation impact:SYSGEN required.You can check with the GNSC for applicability of the above SPRs to RVURs released since publication of this Hotstuff. Please refer to the appropriate softdoc for detailed SPR information, including installation instructions, superseded SPRs, and requisite SPR lists. Note: In some cases, requisite SPRs might have greater installation impact than the SPRs described in this Hotstuff.Document VersionRelease DateDetails2November 28,2025Added information on the problem and fix for Microsoft Access returning -7732 error in T0611 product in L38 & L39.Reference to T7968, which was mentioned in the original HotStuff has been removed. Now, a permanent fix is provided in T06111February 22,2025Initial Version
Operating Systems Affected:NonStop OS L21.11, NonStop OS L22.09, NonStop OS L23.08, NonStop OS L24.08
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.