The HPE ProLiant DL320/DL340 Gen12 system has only one processor. However, on systems that have the optional Systems Insight Display (SID) module, if the server is running a secondary CPLD version older than v1111, the LED at PROC#2 on the (SID) will incorrectly illuminate amber, even though there is no Processor 2 in the system:
Any HPE ProLiant DL320 Gen12 server or ProLiant DL340 Gen12 server configured with an SID and running a secondary CPLD version prior to v1111.Note: The secondary CPLD versions can be found on the iLO webpage.
Since these systems only contain a single processor, this issue can be safely ignored, because there is no "PROC#2."However, CPLD versions v1111 (and later) have the Processor 2 LED set to "off," preventing this issue from occurring.The CPLD version can be updated by the HPE Services and Support team. To obtain the CPLD, contact HPE Support and reference document ID: a00155091en_us.Document VersionRelease DateDetails2December 9, 2025Updated to clarify some information1November 18, 2025Original Document Release.