OPERATIONAL DEFECT DATABASE
...

...
On any HPE ProLiant Gen10 Plus AMD-based 300-series server, if the "AMD SMT Option" is disabled or "Enabled Cores per Processor" is changed, the system will generate an additional warm reset at the "Multiprocessor initialization" phase during Power-On Self-Test (POST).Since an additional reset is expected behavior, and one time use function will become invalid, for example, the One-Time Boot Status:
any HPE ProLiant Gen10 Plus AMD-based 300-series server.
Since the one-time boot does not work when the AMD SMT option is disabled, the AMD SMT option must be enabled in order to use this feature.Document VersionRelease DateDetails2September 19, 2025Updated the resolution section1July 24, 2025Original document release