On an HPE ProLiant ML30 Gen10 Plus with HPE Integrated Lights-Out 5 (iLO 5) firmware v3.11 (or earlier), the Integrated Management Log (IML) may display the logging entries as shown below while the storage device is not installed in the related location indicated by the message.Informational,324,3544,0x0013,Drive Array,0x0030,Hardware,10/07/2024 17:49:06,182: Embedded SATA Storage - Drive at Box 20 Bay 1 status changed to Removed ACTION: 1. Verify cables are good and fully seated. 2. Ensure all drives are fully seated. 3. Verify backplane, controller, and drive compatibility. 4. Replace the defective drive.Caution,348,3551,0x0033,NVMe,0x0002,Hardware,10/28/2024 17:49:13,185: NVMe Storage - Drive at status changed to Invalid ACTION: 1. Verify cables are good and fully seated. 2. Ensure all drives are fully seated. 3. Verify backplane, controller, and drive compatibility. 4. Replace the defective drive.
Any HPE ProLiant ML30 Gen10 Plus with iLO 5 firmware v3.11 (or earlier).
Update to iLO 5 firmware v3.12 (or later).To download iLO 5 v3.12 (or later), perform the following steps:Click the following link:http://www.hpe.com/support/ilo5The page should refresh to display the "DRIVERS AND SOFTWARE" tab and the components that support the selected product. From the "DRIVERS AND SOFTWARE" expandable filter menus on the left side of the page:For further filtering if needed - Select the specific Operating System from the Operating Environment.Locate and select theHPE Integrated Lights-Out 5 v3.12 firmware.click the Revision History tab to locate the latest version.For more important information, review the Release Notes tab.Click theDownloadbutton.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.