An internal error in the CLI response to the#show vlancommand display will occur when a special character is included in the name of a Virtual LAN (VLAN):An internal error occurred.The VLAN table display is incomplete after the offending VLAN that caused the internal error is parsed.Example of the error:To avoid the internal error display, only alphanumeric characters should be used in the VLAN name. The following special characters are allowed:Examples of acceptable names or descriptions are shown below.
This advisory applies to the following HPE M-Series ONYX switches:HPE SN2100M 100GbE 16QSFP28 Half Width Switch [Q2F23A]HPE SN2100M 100GbE 8QSFP28 Half Width Switch [Q2F24A]HPE SN2100M 100GbE 16QSFP28 Power to Connector Airflow Half TAA-compliant [R0P75A]HPE SN2100M 100GbE 16QSFP28 Connector to Power Airflow Half TAA-compliant [R0P76A]HPE SN2010M 25GbE 18SFP28 4QSFP28 Switch [Q9E63A]HPE SN2010M 25GbE 18SFP28 4QSFP28 Power to Connector Airflow TAA-compliant [R0P77A]HPE SN2010M 25GbE 18SFP28 4QSFP28 Connector to Power Airflow TAA-compliant [R0P78A] • HPE SN2700M 100GbE 32QSFP28 Switch [Q2F21A]HPE SN2700M 100GbE 32QSFP28 Power to Connector Airflow TAA-compliant [R0P71A]HPE SN2700M 100GbE 32QSFP28 Connector to Power Airflow TAA-compliant [R0P72A]HPE SN2700M 100GbE 16QSFP28 Switch [Q6M26A]HPE SN2410M 25GbE 48SFP28 8QSFP28 Switch [Q2F22A]HPE SN2410M 25GbE 48SFP28 8QSFP28 Power to Connector Airflow TAA-compliant [R0P73A]HPE SN2410M 25GbE 48SFP28 8QSFP28 Connector to Power Airflow TAA-compliant [R0P74A]HPE SN2410bM 10GbE 48SFP+ 8QSFP28 Switch [Q6M28A]HPE SN2410M 25GbE 24SFP28 4QSFP28 Switch [Q6M27A]HPE SN2410bM 10GbE 24SFP+ 4QSFP28 Switch [Q6M29A]HPE SN3700cM 100GbE 32QSFP28 Power to Connector (P2C) Airflow Switch [R3B14A]HPE SN4600cM 100GbE 64QSFP28 Power to Connector (P2C) Airflow Switch [R6R24A]HPE SN3700M 200GbE 32QSFP28 Power to Connector (P2C) Airflow Switch [R5Z74A]
Only alphanumeric characters encased by quotes are to be used in the name of a VLAN. No other special characters are allowed, with the exception of the above listed special characters, to avoid the internal error display.If this issue occurs, check the running config file or theshow runCLI output for any special characters in the name of a VLAN. If special characters are present, replace the special characters with an allowed character.If further assistance is needed, contactHPE Customer Support.Go toHPE Services - Technical support phone numbersto create a Sales Force Developer Community (SFDC) case. Provide a note and ask for an escalation to the HPE Engineering Resolution Team (ERT) as soon as possible. When opening a case to the HPE ERT team, include the sysdmp files.ContactHPE Servicesif you need assistance with creating an HPE Services support case.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.