On any HPE Synergy 480 Gen11 Compute Module running VMware ESXi 8.0 U3 with a Red Hat Enterprise Linux 9.4/9.5 as a guest operating system, and configured with either of the HPE Synergy network adapters listed in the Scope section below; the network adapter driver in the RHEL 9u4/9u5 Guest operating system cannot initialize the network adapter interfaces when using the PCI passthrough function.When this occurs, errors with the messages "Failed to enable MSI-X", "Ramrod is stuck" can be seen in the dmesg logs:[ 1.707928] QLogic FastLinQ 4xxxx Core Module qed 8.74.6.0[ 1.721541] qede_init: QLogic FastLinQ 4xxxx Ethernet Driver qede 8.74.6.0[ 1.722009] qede 0000:03:00.0: enabling device (0000 -> 0002)[ 1.722816] qede 0000:03:00.0: pci_resource_base = 0xffffa880006e0000pci_resource_len = 0x00008000[ 1.723960] [qed_send_msg2pf:237()]PF[0x00] response: 3 [Type 29][ 1.723963] [qed_vf_pf_rdma_acquire:432()]PF returned status:NOT_SUPPORTED to VFRDMA acquisition request[ 1.724058] [qed_vf_hw_prepare:904()]PF declined RDMA capabilities for VF.Proceeding as L2 only[ 1.725685] [qed_slowpath_vf_setup_int:1656()]No MSI-X vectors are available forRDMA [fp_msix_cnt 14, num_l2_queues 14][ 1.726490] qede 03:00.0: Storm FW 8.72.1.0, Management FW 8.65.6.0 [eth0][ 1.726936] qede 0000:03:02.0: enabling device (0000 -> 0002)[ 1.727957] qede 0000:03:02.0: pci_resource_base = 0xffffa88000c00000pci_resource_len = 0x00080000[ 1.840231] [qed_enable_msix:1119()]Failed to enable MSI-X [Requested 129vectors][rc -22][ 1.840236] [qed_set_int_mode:1152()]Failed to enable MSI-X[ 1.840238] [qed_set_int_mode:1167()]Failed to enable MSI[ 31.153477] [qed_spq_block:212()]Ramrod is stuck [CID ff008000COMMON_RAMROD_PF_START:0x01 PROTOCOLID_COMMON:0x08 echo 0000][ 31.153492] [qed_hw_err_notify:1231()]Ramrod is stuck [CID ff008000COMMON_RAMROD_PF_START:0x01 PROTOCOLID_COMMON:0x08 echo 0000][ 31.153499] [qed_hw_error_occurred:3570()]HW error occurred [Ramrod Failure][ 31.167951] [qed_hw_init_pf:5800()]Function start ramrod failed[ 31.167954] [qed_hw_init:6145()]init phase failed for loadcode 0x10100000 (rc-16)[ 31.192569] [qed_spq_completion:1171()]Failed to find an entry this EQE [echo0000] completes[ 31.193453] qed 03:02.0: Cannot start slowpath[ 31.207779] qede: probe of 0000:03:02.0 failed with error -16The network adapter interface will not be available for use when this error is found.
Any HPE Synergy 480 Gen11 Compute Module running VMware ESXi 8.0 U3 with a Red Hat Enterprise Linux 9.4/9.5 as Guest operating system, and configured with either of the following HPE Synergy network adapters:HPE Synergy 6820C 25/50Gb Converged Network Adapter (P02054-B21)HPE Synergy 4820C 10/20/25Gb Converged Network Adapter (876449-B21)
The network adapter interfaces can be initialized by applying "qed.limit_msix_vectors=128" to the kernel boot parameters of the Red Hat Enterprise Linux 9.4/9.5 Guest operating system.The issue is still under investigation, and this advisory will be updated when additional solutions become available.
Operating Systems Affected:Red Hat Enterprise Linux 9.4, VMware ESXi 8.0, Red Hat Enterprise Linux 9.5
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.