For any HPE platforms running the Linux Operating Systems listed in the Scope section below, AutoDeploy or AutoDeployReboot mode may change to AutoStage after using HPE OneView (and a Synergy Service Pack or Service Pack for ProLiant) to update iSUT from version 5.2.0.0 (or earlier) to 6.0.0.0 (or later).The above issue will not occur if:Updating iSUT from version 5.2.0.0 (or earlier) to 5.3.0.0.Updating iSUT from version 5.3.0.0 to 6.0.0.0.
In the scenario described above, any HPE platforms running the following Operating Systems:Red Hat Enterprise Linux 8Red Hat Enterprise Linux 9SUSE Linux Enterprise Server 15Additional information can be found at the link below.Integrated Smart Update Tools 6.0.0 Release Notes for Windows, Linux, and VMware ESXi
To avoid this issue, install iSUT version6.1.0(or later).If the iSUT mode changed to AutoStage, manually reboot the server to complete the update task, or change the iSUT mode to AutoDeploy or AutoDeployReboot.Revision HistoryDocument VersionRelease DateDetails2August 12, 2025The Resolution section has been updated with the software version containing the solution.1May 13, 2025Original Document Release.
Operating Systems Affected:Red Hat Enterprise Linux 8 Server, Red Hat Enterprise Linux 9, SUSE Linux Enterprise Server 15