When executing the Redfish method,ResetToDefaults, to reset the HPE MR408i-p Gen11 Storage Controller to its default factory settings, a false error message,"400 Bad Request," appears instead of the expected "200 OK" message. This issue affects all HPE MR408i-p Gen11 Storage Controllers and is caused by the controller's inability to respond to iLO commands within the required timeframe.Refer to page 11 of theHPE Storage Controllers – Management overviewfor details.
The following controller is affected by this issue:HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller (P74775-B21)
This issue is resolved inFirmware Package - HPE MR408i-p Gen11 Tri Mode Controller(version 52.32.3-6118 (or later).Revision HistoryDocument VersionRelease DateDetails2September 8, 2025The Resolution was updated with the MR Controller firmware version that resolves this issue.1April 30, 2025Original Document Release.
Operating Systems Affected:OS Independent