After upgrading to SimpliVity OmniStack Software 5.2.0, the following VCenter Alarm may occur: "HPE SimpliVity host's BIOS attributes are not as recommended." This is generated even when there is no difference in the current settings from the recommended BIOS settings.
Any of the following systems after upgrading to SimpliVity OmniStack 5.2.0.129:HPE SimpliVity 380 Gen10HPE SimpliVity 380 Gen10 PlusHPE SimpliVity 380 Gen10 GHPE SimpliVity 325 Gen10 Plus v2HPE SimpliVity 380 Gen11
Starting with SimpliVity Software 5.2.0 there is a new SimpliVity Alarm defined in vCenter. The health check runs monthly and upon host reboot. An alarm is sent to vCenter if the BIOS settings deviate from the recommended settings. The alarm details will identify the specific BIOS attribute(s) that do not match the recommended settings.It has been determined that some of these BIOS attributes can be different, and if the alarm is generated by any of the settings included in the following list of "Ignored BIOS Attributes," it can be ignored safely.In the next SimpliVity Software release, there will be an ignore list to prevent vCenter alarms for the following BIOS attributes.List of ignored BIOS Attributes:AutoPowerOnAllowLoginWithIloCustomPostMessageNicBoot1NicBoot5SecureBootStatusServerConfigLockStatusSgxOwnerEpochEncryptTpmActivePcrsTpmChipIdTpmTypeTpmStateTpmFipsTpm20SoftwareInterfaceStatusUserDefaultsStateUtilityLangtAs a workaround, until the next SimpliVity Software release, acknowledge these alarms or disable the alarm in vCenter. If assistance is needed with the below procedure, contactHPE SimpliVity SupportTo disable the alarm:Select vCenterNavigate to ConfigureSelect Alarm DefinitionSelect "HPE SimpliVity host's BIOS attributes are not as recommended. Check description."Disable this alarmNOTE: With the next SimpliVity Software release there will be a new document providing the recommended BIOS settings for each hardware platform.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.