Offline and Online methods of IO Service Pack Deployment will fail to detect any drive models in HPE Smart Update Manager (SUM) Inventory, when the HDD/SSD drives are connected to MR96xx controllers on HPE Compute Scale-up server 3200 systems. Therefore, drive firmware cannot updated with SUM.
HPE Compute Scale-Up Server 3200 systems configured with any of the following MR96xx controllers will fail to inventory HDD/SSD firmware components for drives connected to the controller:R9N96A HPE MR9660-16i Tri-Mode PCIe4 ControllerR9N97A HPE MR9670-24i Tri-Mode PCIe4 ControllerR9N98A HPE MR9670W-16i PCIe4 ControllerCurrently, there are two supported SSD model families with critical firmware updates available:Bulletin: (Revision) HPE SSD - Potential Data Loss May Occur on Certain SAS PM1643a, PM1653, PM1645a, PM1655 and Certain Other SSDsThis impacts the following HPE SKUs and model numbers with firmware versions prior to HPD3:P49041-H21HPE 7.68TB SAS RI SFF BC MV SSD: VO007680PZXFBP49045-H21HPE 15.36TB SAS RI SFF BC MV SSD: VO015360PZXEUAdvisory: HPE SAS Solid State Drive (SSD) - Certain HPE SASSSDs May Report 01/5D/32 Predictive Failures With No Other Errors Reportedand impacts the following HPE SKUs and model numbers with firmware version prior to HPD3:P49049-H21HPE 1.6TB SAS MU SFF BC MV SSD: MO001600PXMTNP49053-H21HPE 3.2TB SAS MU SFF BC MV SSD: MO003200PXMTVP49057-H21HPE 6.4TB SAS MU SFF BC MV SSD: MO006400PXMUAP49041-H21HPE 7.68TB SAS RI SFF BC MV SSD: VO007680PXMTTP49045-H21HPE 15.36TB SAS RI SFF BC MV SSD: VO015360PXMTUand impacts the following HPE SKUs and model numbers with firmware version prior to HPD2:P63871-B21HPE 1.6TB SAS MU SFF BC FIPS PM7 SSD: MO001600PXVRUP63875-B21HPE 3.84TB SAS RI SFF BC FIPS PM7 SSD: VO003840PXVRRP63879-B21HPE 7.68TB SAS RI SFF BC FIPS PM7 SSD: VO007680PXVRTRun the "storcli2" command to identify the specific drive models and firmware versions in a system:# /opt/MegaRAID/storcli2/storcli2 /call /eall /sall show all | grep -e "Model =" -e Revision
If any of the impacted drive models are running firmware prior to the versions listed above, and are configured behind a MR96xx RAID controller, contact your HPE Support representative for assistance updating the drive firmware. Reference document ID: a00147063
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.