When performing a Logical drive creation via Redfish API with an HPE MR Gen10 Plus or HPE MR Gen11 controller, the operation may fail with an HTTP code 400 or 500. Additionally, the Redfish response will display unreadable text.
Any HPE ProLiant Gen10 Plus and Gen11 servers with the following Integrated Lights-Out firmware versions:Integrated Lights-Out 5 firmware earlier than v3.09Integrated Lights-Out 6 firmware earlier than v1.64With the following HPE MR controllers:MR216i-a Gen10 PlusMR216i-o Gen11MR216i-p Gen10 PlusMR216i-p Gen11MR408i-o Gen11MR416i-a Gen10 PlusMR416i-o Gen11MR416i-p Gen10 PlusMR416i-p Gen11
To resolve this issue, upgrade to the following versions:Integrated Lights-Out 5 firmware version 3.09 or laterIntegrated Lights-Out 6 firmware version 1.64 or laterTo download iLO 6 v1.64 (or later) or iLO 5 v3.09 (or later), perform the following steps:Click the following link:http://www.hpe.com/support/ilo6orhttp://www.hpe.com/support/ilo5The page should refresh to display the "DRIVERS AND SOFTWARE" tab and the components that support the selected product. From the "DRIVERS AND SOFTWARE" expandable filter menus on the left side of the page:For further filtering if needed - Select the specific Operating System from the Operating Environment.Locate and select theHPE Integrated Lights-Out 6 v1.64 firmwareorHPE Integrated Lights-Out 5 v3.09 firmware.click the Revision History tab to locate the latest version.For more important information, review the Release Notes tab.Click theDownloadbutton.
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.