HPE Cray XD670 fails during POST after applying BIOS parameter "Power Policy Quick Settings = Best Performance” and reboot. During POST you may see the following message: The issue is caused by the following: Changing the "GBT0133: Power Policy Quick Setting" in the BIOS to "Best Performance."
HPE Cray XD670
To resolve this issue perform the following steps: (1) Power down the HPE Cray XD670 system. (2) Flash system BIOS without preserving the BIOS parameter. (3) Power on. (4) After XD670 server boots, apply the custom BIOS parameters. However, do not control the “GBT0133: Power Policy Quick Settings”. Best Performance Items Table ItemBest PerformanceRedfish Chipset -> Advanced Power Management Configuration -> CPU P State Control -> SpeedStep(Pstates) Enable EagleStream0081 Chipset -> Advanced Power Management Configuration -> CPU P State Control -> Turbo Mode Enable EagleStream0082 Chipset -> Advanced Power Management Configuration -> CPU C State Control -> Enable Monitor MWAIT Enable EagleStream0084 Chipset -> Advanced Power Management Configuration -> CPU C State Control -> CPU C6 report Disable EagleStream0085 Chipset -> Advanced Power Management Configuration -> CPU C State Control -> Enhanced Halt State (C1E) Disable EagleStream0086 Chipset -> Advanced Power Management Configuration -> Package C State Control -> Package C State C0/C1 state EagleStream0087 Chipset -> Advanced Power Management Configuration -> CPU - Advanced PM Tuning -> Energy Perf BIAS -> Power Performance Tuning BIOS control EPB EagleStream0088 Chipset -> Advanced Power Management Configuration -> CPU - Advanced PM Tuning -> Energy Perf BIAS -> ENERGY_PERF_BIAS_CFG Mode Performance EagleStream0089 Chipset -> Advanced Power Management Configuration -> Hardware PM State Control -> Hardware P-States Native mode EagleStream0083 Chipset -> Power Policy -> Enable LP [Global] Enable EagleStream0001 Chipset -> Processor Configuration -> Hardware Prefetcher Enable EagleStream0002 Chipset -> Processor Configuration -> Adjacent Cache Prefetch Enable EagleStream0004 Chipset -> Processor Configuration -> DCU streamer Prefetcher Enable EagleStream0005 Chipset -> Processor Configuration -> DCU IP Prefetcherh Enable EagleStream0006 Chipset -> Processor Configuration -> VMX Enable EagleStream0007 Chipset -> UPI Configuration -> UPI General Configuration -> SNC SPR CPU : Enable SNC4 (4-clusters) EagleStream0040 EMR CPU : SNC2 (2-clusters) Chipset -> Memory Configuration -> Enforce POR Disable EagleStream0045 Chipset -> UPI Configuration -> UPI General Configuration -> Stale AtoS Enable EagleStream0041 Chipset -> UPI Configuration -> UPI General Configuration -> LCC dead line alloc Disable EagleStream0044 Chipset -> Memory Configuration -> Memory RAS Configuration -> Patrol Scrub Disable EagleStream0060 Chipset -> IIO Configuration -> Intel VT for Directed I/O (VT-d) -> Intel® VT for Directed I/O Enable EagleStream0064 Chipset -> Processor Configuration -> Extended APIC Enable EagleStream0008 Chipset -> Power Policy -> Hyper-Performance Level 1 GBT0252 Chipset -> Power Policy -> Turbo Frequency mode Disable GBT0254