Upgrading HPE Integrated Lights-Out 6 (iLO 6) to firmware v1.61 and iLO 5 to firmware v3.06 may cause the iLO to be inaccessible from subnets other than the subnet iLO is on. The iLO would be accessible from the subnet it is on. The iLO also records the following critical eventDuplicate IP address <xx.y> detected on network.The critical event is recorded when the iLO is reset.
Any HPE system with iLO 6 or iLO 5.
To resolve this issue, update to iLO 5 firmware v3.07 (or later) or iLO 6 firmware v1.62 (or later).To download iLO 6 v1.62 (or later) or iLO 5 v3.07 (or later), perform the following steps:Click the following link:http://www.hpe.com/support/ilo6orhttp://www.hpe.com/support/ilo5The page should refresh to display the "DRIVERS AND SOFTWARE" tab and the components that support the selected product. From the "DRIVERS AND SOFTWARE" expandable filter menus on the left side of the page:For further filtering if needed - Select the specific Operating System from the Operating Environment.Locate and select theHPE Integrated Lights-Out 6 v1.62 firmwareorHPE Integrated Lights-Out 5 v3.07 firmware.click the Revision History tab to locate the latest version.For more important information, review the Release Notes tab.Click theDownloadbutton.