On any HPE ProLiant DL560 Gen11 server, a Red Screen error (RSOD) may occur when trying to obtain System Health Data through the embedded diagnostics in System Utilities.This occurs when the steps below are followed:Access System Utilities > Embedded Applications > Embedded DiagnosticsSystem Health > Getting System Health DataAt this point, the RSOD is encountered.
Any HPE ProLiant DL560 Gen11 server.
This is not a hardware issue; do not replace any hardware.This issue has been resolved in HPE Intelligent Provisioning 4.35, available for downloadhere.If the issue has already occurred, reboot the server to recover the system.Note:To ensure that you have selected the latest version of the firmware/driver, click the Revision History tab to check if a new version of the firmware/driver is available. For more important information, review the Release Notes tabRevision HistoryDocument VersionRelease DateDetails2November 13, 2024Updated RSOD capture.1October 3, 2024Original Document Release.
Operating Systems Affected:Not Applicable