Loading...
Loading...
After the GET call, i.e., /rest/server-hardware/UUID, is made in the HPE OneView REST API, the response body may show an incomplete or duplicate MAC address list if the target server is installed with Intel E810-based network cards; for example:Intel E810‑XXVDA2 Ethernet 10/25Gb 2‑port SFP28 Adapter for HPESKU # P08443-B21Intel E810‑XXVDA2 Ethernet 10/25Gb 2‑port SFP28 OCP3 Adapter for HPESKU # P10106-B21Intel E810‑XXVDA4 Ethernet 10/25Gb 4‑port SFP28 Adapter for HPESKU # P08458-B21Intel E810‑XXVDA4 Ethernet 10/25Gb 4‑port SFP28 OCP3 Adapter for HPESKU # P41614-B21
HPE OneView version 9.10 or earlier with HPE servers that support the following cards:Intel E810‑XXVDA2 Ethernet 10/25Gb 2‑port SFP28 Adapter for HPESKU # P08443-B21Intel E810‑XXVDA2 Ethernet 10/25Gb 2‑port SFP28 OCP3 Adapter for HPESKU # P10106-B21Intel E810‑XXVDA4 Ethernet 10/25Gb 4‑port SFP28 Adapter for HPESKU # P08458-B21Intel E810‑XXVDA4 Ethernet 10/25Gb 4‑port SFP28 OCP3 Adapter for HPESKU # P41614-B21
This issue is fixed by upgrading toHPE OneView 9.20.If the issue has already occurred, perform the following workaround:Enter a GET call in the REST API URI:/rest/server-hardware/UUID/networkAdaptersThe solutions will provide the correct MAC addresses.Document VersionRelease DateDetails2November 14, 2024Updated the Resolution with the permanent fix.1October 01, 2024Original Document Release.
Operating Systems Affected:Not Applicable