When HPE SR Gen10 controllers (running firmware version 7.11) and Gen10 Plus/Gen11 controllers (running firmware version 03.01.30.106) are booted without any drives attached to the controller, the controller is incorrectly displayed as a SATA Storage System and the controller's name is reported with "SATA Storage System" in the HPE Integrated Lights-Out (iLO) Storage tab:A controller name is typically expected to be reported in the iLO Storage tab, as shown below:
This issue occurs on the following HPE SR controllers and firmware versions:HPE SR Gen10 Controllers (version 7.11)HPE SR Gen10 Plus Controllers (version 03.01.30.106)HPE SR Gen11 Controllers (version 03.01.30.106)
This issue is resolved in the following HPE SR controller firmware:HPE SR Gen10 Controller firmware version 7.43:HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllersHPE SR Gen10 Plus and Gen11 Controller firmware version 03.01.33.044:HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 ControllersWorkaroundTo resolve this issue so the iLO displays the controller and not a SATA Storage System, attach any supported drive to the controller.After a drive is inserted, a new Redfish Storage resource instance is re-created with a new URI. For example, the Redfish Storage resource for SATA Storage System is generated with the below URI when the system is booted:/redfish/v1/Systems/1/Storage/DA000007After a drive is inserted, the above Redfish Storage resource is removed, and a new Redfish Storage resource is generated for the controller with new URI, as shown below:/redfish/v1/Systems/1/Storage/DE009000Revision HistoryDocument VersionRelease DateDetails2May 28, 2025Updated the Resolution section with the fix1August 23, 2024Original Document Release
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.