On any of the servers mentioned in the Scope section below, running System ROM version 1.64 (or earlier), a PCR0 validation may fail because a number of servers may report a different PCR0 value despite having identical configurations and ROM versions.The PCR0 hash validation can be executed using the TPM log tool, which in this case will show that the Digest value is different between the units:
Any of the following servers:HPE ProLiant DL325 Gen11 serverHPE ProLiant DL345 Gen11 serverHPE ProLiant DL365 Gen11 serverHPE ProLiant DL385 Gen11 server
The difference in values does not cause any adverse effect on the server and the server will continue to function as expected.This issue has been addressed with System ROM 1.66 (or later):ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL345 Gen11 (A56) ServersROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385 Gen11 (A55) ServersNote: To ensure that you have selected the latest version of the firmware/driver, click the Revision History tab to check if a new version of the firmware/driver is available. For more important information, review the Release Notes tab.Revision HistoryDocument VersionRelease DateDetails2September 10, 2024Updated Resolution with permanent fix.1July 5, 2024Original Document Release.
Operating Systems Affected:Not Applicable