For HPE ProLiant/Synergy Gen10 Plus Intel-Based Servers, after applying the Server profile with BIOS Workload Profile set to "Virtualization-Max Performance," the following BIOS settings will be displayed as being inconsistent.Maximum Uncore FrequencyMinimum Uncore FrequencyWhen this occurs, the Profile will display a yellow warning alert, "BIOS Settings do not match the expected values."This occurs because the System ROM changes the values for these settings internally to 24 and 8 respectively, whenever the workload profile is set to "Virtualization-Max Performance."Once the profile has been applied and the BIOS settings actuated, OneView begins to flag these settings as inconsistent since these setting have values of 0 on the OneView profile, which does not match the values in the BIOS.
Any HPE ProLiant/Synergy Gen10 Plus Intel-Based Servers and the following Gen11-based servers:HPE Synergy 480 Gen11HPE ProLiant DL380 Gen11HPE ProLiant DL360 Gen11HPE ProLiant DL380a Gen11HPE ProLiant ML350 Gen11HPE ProLiant DL560 Gen11HPE ProLiant DL110 Gen11HPE ProLiant DL320 Gen11HPE Compute Edge Server e930t
As a workaround for the Max/Min UnCore Frequency settings, set the desired values in the profile to the actual values that the System ROM applies to these settings and re-apply the profile.This advisory will be updated if additional solutions become available.Document VersionRelease DateDetails2August 13, 2025Updated to indicate Gen11 systems that are impacted1June 25, 2024Original document release
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.