For any HPE SN M-series switches listed in the Scope section below, and with the NTP configured to use DNS, the NTP will stop functioning right after updating ONYX to version 3.10.4404 or 3.10.4408. This issue does not affect other protocols or settings using DNS.
In the scenario described above, any HPE SN M-series switches running ONYX version 3.10.4404 or 3.10.4408:HPE SN2100M 100GbE 16QSFP28 Half Width Switch (Q2F23A)HPE SN2100M 100GbE 8QSFP28 Half Width Switch (Q2F24A)HPE SN2100M 100GbE 16QSFP28 Power to Connector Airflow Half TAA-compliant (R0P75A)HPE SN2100M 100GbE 16QSFP28 Connector to Power Airflow Half TAA-compliant (R0P76A)HPE SN2010M 25GbE 18SFP28 4QSFP28 Switch (Q9E63A)HPE SN2010M 25GbE 18SFP28 4QSFP28 Power to Connector Airflow TAA-compliant (R0P77A)HPE SN2010M 25GbE 18SFP28 4QSFP28 Connector to Power Airflow TAA-compliant (R0P78A)HPE SN2700M 100GbE 32QSFP28 Switch (Q2F21A)HPE SN2700M 100GbE 32QSFP28 Power to Connector Airflow TAA-compliant (R0P71A)HPE SN2700M 100GbE 32QSFP28 Connector to Power Airflow TAA-compliant (R0P72A)HPE SN2700M 100GbE 16QSFP28 Switch (Q6M26A)HPE SN2410M 25GbE 48SFP28 8QSFP28 Switch (Q2F22A)HPE SN2410M 25GbE 48SFP28 8QSFP28 Power to Connector Airflow TAA-compliant (R0P73A)HPE SN2410M 25GbE 48SFP28 8QSFP28 Connector to Power Airflow TAA-compliant (R0P74A)HPE SN2410bM 10GbE 48SFP+ 8QSFP28 Switch (Q6M28A)HPE SN2410M 25GbE 24SFP28 4QSFP28 Switch (Q6M27A)HPE SN2410bM 10GbE 24SFP+ 4QSFP28 Switch (Q6M29A)HPE SN3700cM 100GbE 32QSFP28 Power to Connector (P2C) Airflow Switch (R3B14A)HPE SN4600cM 100GbE 64QSFP28 Power to Connector (P2C) Airflow Switch (R6R24A)HPE SN3700M 200GbE 32QSFP28 Power to Connector (P2C) Airflow Switch (R5Z74A)
To avoid this issue, update ONYX to version3.10.4504(or later).As a workaround, use the IP address of the NTP server, as shown below:SN2010 [2010MLAG: standby] (config) # ntp server <IP address>Additional information can be found at page 162 of the link provided below.MLNX-OS for HPE StoreFabric M-Series Ethernet Switch User ManualRevision HistoryDocument VersionRelease DateDetails2October 10, 2024The Resolution section has been updated with the ONYX version containing the solution.1June 05, 2024Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.