On an HPE server with HPE Integrated Lights-Out 5 (iLO 5) or iLO 6, Redfish "ethernetinterfaces" reports the "UefiDevicePath" only for the first NIC port interface, but not for the all the remaining NIC port interfaces.This can be observed as follows:Connect to iLO 5 or iLO 6 using iLORest or Redfish client tool.Perform a select or GET on "/redfish/v1/Systems/1/EthernetInterfaces/”Perform a list to list all the content of "ethernetinterfaces” obtained from above.Verify that there is noUefiDevicePath for 2nd NIC ports.Ethernet NIC Port 1 and Port 2:
Any HPE ProLiant Gen10, HPE ProLiant Gen10 Plus, HPE ProLiant Gen 11 server with iLO 5 or iLO 6 and an HPE network interface controller with multiple ports.
As a workaround, to get UefiDevicePath on all network interface controller ports, perform the following steps:From RBSU, Enable PXE boot on all the network interface controller ports:Once PXE is enabled on all NIC ports, UefiDevicePath for all NIC ports can be retrieved from the Redfish boot source endpoint as follow:On Gen10 servers: use/redfish/v1/systems/1/bios/bootOn Gen10 Plus servers: use /redfish/v1/Systems/1/bios/oem/hpe/bootOn Gen11 servers: use /redfish/v1/Systems/1/bios/oem/hpe/bootThis issue will be addressed for the HPE ProLiant Compute Gen12. For HPE ProLiant Gen10, HPE ProLiant Gen10 Plus, and HPE ProLiant Gen11 servers, use the workaround stated above.Document VersionRelease DateDetails2November 4, 2024Added fix, HPE ProLiant Compute Gen12.1March 8, 2024Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.