...
On an HPE ProLiant Gen10 or Gen10 plus or HPE ProLiant Gen11 server running Linux and configured with a Broadcom controller with multiple SAS or SATA hard drives, the drive firmware will fail to update in Smart Update Manager (SUM) Integrated Smart Update Tools (iSUT) mode and display the following example message: Deploy completed with errors. Deployment failed for firmware-hdd-bdfb8e99d9-HPD6-3.1.x86_64.rpm. Task has moved to Exception state in iLO Repository Although the firmware does not update on multiple hard drives, the operation or functionality of the hard drive is not affected. This can be observed when performing the following steps: Connect multiple (for example four Seagate Skybolt 512n SAS) hard drives to a Broadcom controller. Install AMS (Agentless Management Service) and iSUT (Integrated Smart Update Tool) on a target Linux OS, for example, Red Hat Enterprise Linux 9.1. Run the command in the command prompt: sut -set mode=autodeployreboot Navigate to Extracted Service Pack for ProLiant (for example, Gen10 SPP Version 2022.09.01.00 - SPP2022090100.2022_0930.1.iso) folder path in Jump station. Run launch_sum.sh, a SUM page will open. Click on Nodes->Add Node. A dialog box appears; under the nodes section enter the iLO IP of the server uncheck "Automatically add associated nodes box" and for the node type, select as iLO. Select SPP baseline, enter the iLO username and password, and select Add. After completion of fetching details, nodes get added, and clicking on inventory, select components which required an update in review and deploy page, and click on deploy. After deploying, the page displays "update returned an error." On the Node page, an error gets displayed, for example, 172.17.31.91: Deploy completed with errors. Deployment failed for firmware-hdd-bdfb8e99d9-HPD6-3.1.x86_64.rpm. Task has moved to Exception state in iLO Repository.
Any HPE ProLiant Gen10 or Gen10 plus or Gen11 server running Linux and configured with a Broadcom controller in SUM iSUT mode with any of the HPE SAS or SATA hard drives: Drive model Part number EG000600JWJNP 872477-B21 EG000600JXLVV 872477-B21 EG001200JXLWA 872479-B21 EG001200MXJQU P28622-B21 VK001920GZXQV P18426-B21 VK003840GZXRH P18428-B21 VK007680GZXRT P18430-B21 VK000960GZXQU P18424-B21 VK000480GZXRF P18422-B21 VK000240GZXRU P18420-B21 MB016000GZYVV P23449-B21 MB018000GYCLL P37678-B21 MB014000GZYVU P09163-B21 MB012000GZYVT 881785-B21 VK001920GZCNH P18426-B21 VK000480GZCNE P18422-B21 VK000960GZCNF P18424-B21 VK003840GZCNK P18428-B21
Service Pack for ProLiant (SPP) 2024.04.00.00 contains the drive firmware that supports the firmware update with multiple hard drives connected to a Broadcom controller in SUM iSUT mode. To download the SPP Version 2024.04.00.00 (or later), perform the following steps: Click the following link: Hewlett Packard Enterprise Support Center Enter a product name (e.g., "Service Pack for ProLiant") in the text search field and wait for a list of Suggested Products to display. From the Suggested Products list displayed, identify the desired product and select it. The page should refresh to display the "DRIVERS AND SOFTWARE" tab and the components that support the selected product. From the "DRIVERS AND SOFTWARE" expandable filter menus on the left side of the page: Select the Software Type - (insert the specific filter here, e.g. "Firmware") Select the Software Sub Type - (insert the specific filter here, e.g. "Driver - System Management") For further filtering if needed - Select the specific Operating System from the Operating Environment. Locate and select the Service Pack for ProLiant Version 2024.04.00.00 (or later). Note: To ensure that you have selected the latest version of the firmware/driver, click the Revision History tab to check if a new version of the firmware/driver is available. For more important information, review the Release Notes tab. Click the Download button. As a workaround, firmware can be updated using the standalone method by performing the following: Install the firmware rpm using the following command: rpm -ivh This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location. The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd--*' folder is based on the version of the rpm installed in the first step above. To install firmware, execute ONE of the following commands: 3a. ./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location OR 3b. /setup in the '/usr/lib/x86_64-linux-gnu/firmware-hdd--*' location The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory. To uninstall the rpm, run the following command: rpm -e The rpm filename without the '.rpm' extension. Document Version Release Date Details 2 April 17, 2024 Updated Resolution with fix, MarMSB24 SPP SPP2024040000.2024_0414.17.iso. 1 February 7, 2023 Original Document Release. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: HPE Email Preference Center NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document.