An HPE ProLiant Gen9-series server with iLOrest version 3.3 or version 3.5 is unable to set or change the admin password when using either of the commands below:When typing the following command:iLOrest > setpassword --currentpassword None --newpassword Password1The following is displayed, erroneously stating the operation completed successfully:Added the following patch:{"AdminPassword": "Password1"}Added the following patch:{"OldAdminPassword": "None"}Committing changes...The operation completed successfully.The session will now be terminated. login again with updated credentialsin order to continue. Logging session out.ORWhen attempting to use the new password to change the password again using the command below:[root@]# ilorestliLOrest : RESTful Interface Tool version 3.3.0.0 Copyright (c) 2014-2021Hewlett Packard Enterprise Development LPiLOrest > login Discovering data...DoneiLOrest > setpassword --currentpassword Password1 --newpassword NoneThe same output is displayed, erroneously stating the operation completed successfully:Added the following patch:{"AdminPassword": "Password1"}Added the following patch:{"OldAdminPassword": "None"}Committing changes...The operation completed successfully.The session will now be terminated. login again with updated credentialsin order to continue. Logging session out.However, when rebooting the server and pressing F10, a password to enter BIOS is not required.This does not affect existing passwords.
Any HPE ProLiant Gen9-series servers with iLOrest version 3.3 or version 3.5 attempting to set or change the admin password.
This issue is resolved iniLOrest version 3.6(or later).Workaround:Boot to F10 and manually set and or change the UEFI BIOS password.Revision HistoryDocument VersionRelease DateDetails2November 22, 2024The Resolution was updated with the version of iLOrest that resolves this issue.1August 19, 2022Original Document Release
Operating Systems Affected:Red Hat Enterprise Linux 7 Server, Red Hat Enterprise Linux 8 Server
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.