Document VersionRelease DateDetails204-26-2021The Resolution section has been updated with the firmware version containing the solution.108-07-2020Original document release.On an HPE ProLiant Gen9/Gen10 Server Blade configured with a Virtual Connect module and 9 (or more) virtual functions defined in the server profile by HPE OneView or HPE Virtual Connect Manager, and with either an HPE FlexFabric 20Gb 2-port 650M Adapter or HPE FlexFabric 20Gb 2-port 650FLB Adapter, the adapter may display a link down after performing a firmware update to version 12.0.1216.0.Once the firmware update has completed, the server blade will undergo a system reboot, and half of the virtual functions (1:1e through 1:1h and 1:2:e through 1:2h) may display a link down state in the Operating System. Performing another system reboot does not resolve this issue.
An HPE FlexFabric 20Gb 2-port 650FLB Adapter (700763-B21) or HPE FlexFabric 20Gb 2-port 650M Adapter (700767-B21) with firmware version 12.0.1110.10 (or earlier), in the scenario described above.
This issue has been resolved in the following HPE FlexFabric 20Gb 2-port 650M/650FLB Adapter firmware version:AdapterSpeedUniversal Boot ImageFirmwareUEFIBoot BiosHPE FlexFabric 20Gb 2-port 650FLB Adapter20Gb12.0.1277.012.0.1336.012.0.1269.012.0.1171.0HPE FlexFabric 20Gb 2-port 650M Adapter20Gb12.0.1277.012.0.1336.012.0.1269.012.0.1171.0HPE Blade Firmware Flash for Emulex Mezzanine CNAs for VMware vSphere 7.0HPE Blade Firmware Flash for Emulex Mezzanine CNAs for VMware vSphere 6.7HPE Firmware Flash for Emulex CNAs for VMware vSphere 6.5HPE Blade Firmware Flash for Emulex Mezzanine CNAs for Microsoft Windows Server 2012R2/2016/2019(x64)HPE Blade Firmware Flash for Emulex Mezzanine CNAs for Linux (x64)As a workaround, and in order to resolve this issue, power off the server, unassign the server profile, and then reassign the server profile.If using HPE OneView, perform the following steps to unassign and reassign the server profile:Power off the affected server.Log into OneView.SelectServer Profilesfrom the Dashboard.Select the affected profile in the left side listings.Editthe affected profile.Selectunassignedfrom theServer Hardwaredropdown menu.ClickOKto apply the configuration.Select the affected profile in the left side listings.Editthe affected profile.From theServer Hardwaredropdown menu, select the server hardware that the profile was previously assigned to.ClickOKto apply the configuration.If using HPE Virtual Connect Manager, perform the following steps to unassign and reassign the server profile:Power off the affected server.Log into the Virtual Connect Manager.SelectServer Profilesfrom the left menu.Editthe affected server profile.Unassignthe profile from the selected server bay.SelectApplyto save the configuration.Editthe same affected profile.Assignthe profile to the blade bay it was previously assigned to.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP:For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to theNavigation Tips document.SEARCH TIP:For hints on locating similar documents on HPE.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.