After installing PowerPath for Windows 6.1 on a Windows 2016, we see the following alerts during the cluster validation: The following drivers are older than the installed version of the Operating System: EMC PowerPath Data Migration Manager: 10/17/2016 12:00:00 AM EMC PowerPath DSM for CLARiiON: 9/27/2016 12:00:00 AM EMC PowerPath DSM for DELL SC: 10/17/2016 12:00:00 AM EMC PowerPath DSM for Generic: 9/27/2016 12:00:00 AM EMC PowerPath DSM for Invista: 9/27/2016 12:00:00 AM EMC PowerPath DSM for Symmetrix: 9/27/2016 12:00:00 AM EMC PowerPath DSM for XtremIO: 9/27/2016 12:00:00 AM EMC PowerPath Generic Purpose Extension: 10/17/2016 12:00:00 AM EMC PowerPath Multipath Extension: 11/20/2016 12:00:00 AM EMS Device Bus: 11/7/2016 12:00:00 AM HP FlexFabric 10Gb 2-port 554M Adapter: 8/27/2016 12:00:00 AM HP FlexFabric 10Gb 2-port 554M Adapter: 8/9/2016 12:00:00 AM iLO 4 (CHIF): 7/29/2016 12:00:00 AM Matrox G200eh (HP) WDDM 2.0: 7/12/2016 12:00:00 AM PowerPath Devices: 9/27/2016 12:00:00 AM
PowerPath for Windows 6.1 is dated September and October 2016 predating the date of Windows 2016.
No resolution needed, the alert is cosmetic. PowerPath 6.1 is qualified and fully supported on Windows Server 2016. Note: PowerPath 6.1 is now End Of Life and it is recommended to upgrade to PowerPath 6.3 or later.