Loading...
Loading...
Customer upgraded CloudLink to 8.x outside of the RCM package. After the upgrade, the CloudLink servers cannot be inventoried. Upgrading CloudLink to version 8.x while the PFxM version is 3.8.7 or lower results in failed inventory API calls to CloudLink: Device_Inventory_logs/clc-172.31.xx.x "msg": "REST API call failed. Status: 405.\n Failed to extract error and description: No JSON object could be decoded. Raw body: <oauth><error_description>Request method 'GET' not supported</error_description><error>method_not_allowed</error></oauth>", "warnings": [ "Failed to execute REST API call on CloudLink Center cluster member 172.31.xx.x.\n The error is: Failed to perform HTTP(s) request: <urlopen error [Errno 113] No route to host>" Impact CloudLink 8.x servers aren't in inventory and can't be controlled via PowerFlex Manager.
CloudLink 8.x REST API changed from 7.x. PFxM version 3.8.7 and lower is running the deprecated CloudLink API, compared to CloudLink version 8.x.
Upgrade the PFxM version to the version that supports CloudLink 8.x. PFxM 3.8.8 is shipped with CloudLink version 8.1.1. PowerFlex: CloudLink Support Matrix Impacted Versions Not a PFMP issue.
Click on a version to see all relevant bugs