After upgrading the Dell Automation Platform (DAP) to version 2.1.1.0 (DDPC 4.3.0.0), one or more NativeEdge endpoints disappear from the orchestrator. The following symptoms are observed: One or more NativeEdge devices are no longer visible in the orchestrator after a successful upgrade. The affected device may still appear in the Portal assets page with a status of Disconnected . The device is powered on, running NativeEdge OS, and attempting to connect — but the orchestrator has no corresponding record. The option to delete the device from the Portal is grayed out. The factory ISO image may not be available for download from Portal > Support > Advanced Options > Download Factory ISO. Repeated errors appear in hzp-inventory-svc logs, for example: unable to update vm list for service tag: <service_tag> — sql: no rows in result set unable to find ece inventory by service tag <service_tag> — sql: no rows in result set endpoint not found
This issue is caused by a bug in the ne-endpoint-svc data migration job ( ne-endpoint-svc-data-migration ) that runs as a Helm post-upgrade hook during the DAP 2.1.1.0 / DDPC 4.3.0.0 upgrade. Root cause — cleanupSoftDeletedEndpoints deletes by service tag instead of record ID The migration job performs the following steps: Upserts active endpoints from the legacy table ( public.endpoint ) into the new schema table ( edge.endpoint ). This step completes successfully. Calls cleanupSoftDeletedEndpoints , which iterates through every soft-deleted (historically failed) row in public.endpoint . For each row, it reads the service tag and calls DeleteByServiceTag() on edge.endpoint . This call deletes any endpoint that has the matching service tag — regardless of whether it is the same record. If the same service tag exists in both a stale soft-deleted row and the newly migrated live row, the live row is deleted. Hard-deletes all source rows from public.endpoint . Pre-condition The affected device must have a stale soft-deleted row in the database — a record from a previous failed or incomplete onboarding attempt that was never purged. When such a row exists alongside the active live row for the same device (same service tag), the cleanup step above incorrectly deletes the live row. The migration job exits with status 0 and reports success, so the deletion is not immediately visible.
Please open a service request with Customer Support for assistance.
Click on a version to see all relevant bugs