In iDRAC GUI, transceiver inventory details are not present in following locations: Under System > Inventory > Hardware Inventory Under System > Overview > Components > Network Devices > (CX-6 LX NIC Slot) > (Port where transceiver is connected) The inventory details are also not visible via other methods such as RACADM or Redfish Inventory details are visible for transceivers connected to other OCP NIC adapters.
This issue occurs because the CX-6 LX adapter handles the inventory request from iDRAC differently than other NVIDIA adapters. While iDRAC10 uses a standard OEM NC-SI command to read transceiver details from all NVIDIA adapters, the CX-6 LX adapter does not return the transceiver inventory data in response to the request.
The issue is tentatively planned to be addressed in the upcoming iDRAC10 version 2.10.30.50 , targeted for release by March 2027 .