Gen6 nodes fail to boot up with the following errors reported. 2019-11-06T09:01:08KST: Test Journal exited with error - Checking Battery Health... Unable to arm for vault. 2019-11-06T09:37:30KST: Test Journal exited with error - Checking Battery Health... Unable to arm for vault. 2019-11-06T09:43:37KST: Test Journal exited with error - Checking Battery Health... Unable to arm for vault.************************************************************ * Extended POST Messages ************************************************************INFORMATION:POST Start WARNING:PMP Partition not found INFORMATION:Firmware Update Skipped Due To Memory Persistence Active ************************************************************EndTime: 11/06/2019 00:40:54.... Storage System Failure - Contact your Service Representative ...ErrorCode: 0x00000420 ErrorDesc: FRU: SSD0 FRU Device: M.2 SATA 0 <---------------------------- Description: Storage device not found Error! <---------------------------- Rev: 26.86 Drive Presence Check* P/N: S/N: EndError: ErrorTime: 11/06/2019 00:40:40
M.2 vault card cannot be detected.
Replace M.2 vault card. If the node still cannot boot up with the same error even after M.2 vault card replacement, replace the compute node.