2024/06/18-04:08:49 (GMT), [SCN-1001], 6077, SLOT 2 | FFDC | CHASSIS, CRITICAL, ED_DCX7_8B, SCN queue overflow for process 0.weblinker.fcg 2024/06/18-04:08:49 (GMT), [SCN-1001], 6078, SLOT 2 | FFDC | CHASSIS, CRITICAL, ED_DCX7_8B, SCN queue overflow for process 0.weblinker.fcg RAS logs: 2024/06/18-04:03:44:626847 (GMT), [C5-5668], 0, SLOT 2 | CHASSIS | PORT 3/40, ERROR, ED_DCX7_8B, S3,P40(73): Port Fault: Hard 0(2) fault1=100 fault2=5 (0x64 0x0 0x0), OID:0x43328809, SPOID:0x43368128, c 2024/05/24-10:23:16 (GMT), [MS-1009], 742, SLOT 2 | FID 128 | PORT 4/17, ERROR, BCC_CORE_SAN_05, RLIR event Slot/Port 4/17 (0x0C7100) Device Port Tag is 0x0333,Loss of Signal or Synchronization. The diag.log file, extracted from the supportsave bundle, contains critical errors that require examination. Below are the excerpts from dial.log: 2024/06/15-00:02:42:595136 (GMT), [C5-5668], 0, SLOT 2 | CHASSIS | PORT 11/40, ERROR, ED_DCX7_8B, S11,P616(73): Port Fault: Hard 0(2) fault1=100 fault2=5 (0x64 0x0 0x0), OID:0x43b28809, SPOID:0x43b68128, c5
Flapping from few devices would have caused disruption that weblinker could not keep up with the queue caused by all the state changes. Weblinker faces challenges due to any misbehaving device that strains it. Whether it is a flapping ISL or port faults, such issues warrant a review of the RAS log for disruptive events.
Ports which are misbehaving (flapping ISL or port faults) must be investigated.